Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Log in to ProTrack Warehouse.
  2. Select the Standards tab under the Configuration menu and the Standards screen appears.

    image
    imageStandards.jpg
    titleFig.212 Standards


    Standards Tab Descriptions

    Tab

    Descriptions

    Create Standards

    Displays the details of a work standard.

    Assign Determinant

    Displays all the determinants associated with the selected standard.

    Fatigue

    Displays all the static and progressive fatigue factors associated with the selected standard.

    Table 50. Standards Tab Descriptions
    Standards Field Descriptions

    Field

    Description

    Standard Name

    Type Standard name, which is alphanumeric (Combination of Alphabets and Numbers).

    Standard Id

    Auto generated by ProTrack Warehouse.

    Standard Type

    Only 'WMS' type is supported.

    Calculate Horizontal Travel

    To calculate horizontal travel, click 'Yes'. If not click 'No'.

    Calculate Vertical Travel

    To calculate vertical travel, click 'Yes'. If not click 'No'.

    Re-trip

    To calculate re-trip standard time, select the Re-trip check box and type the Re-trip Standard Time.

    Equipment Capacity Unit

    Select the equipment capacity units by selecting the check boxes to the left of Lines, Units, Weight, or Volume.

    Default Equipment

    Select the default equipment type from the Default Equipment list.

    Description

    Type Description not more than 250 characters.

    Table 51. Standards Field Descriptions

...

  1. Type a unique Standard Name. The Standard ID is generated automatically.
  2. If you want to Calculate Horizontal Travel, click 'Yes'. If not click 'No'.
  3. If you want to calculate vertical travel, click 'Yes'. If not click 'No'.
  4. To calculate re-trip standard time, select the Re-trip check box and type the Re-trip Standard Time.
  5. Select the default equipment type from the Default Equipment list and entry capacity units by selecting the check boxes, Lines, Units, Weight, or Volume.
  6. Type Description.
  7. To assign determinants to the standard, click the 'Assign Determinant' tab and the Standards screen appears with the Standard Name field and a blank 'Determinant' list.

    image
    imageStd Assign.jpg
    titleFig.213 Standards - Assign Determinants


  8. You can search for the particular determinants by clicking the 'Select Determinant' link.

    image
    imageStd Select.jpg
    titleFig.214 Standards - Select Determinants


  9. Provide the search criteria in the Name field or selecting the Determinant level or Work from the respective lists and click Image Added. The determinants will be listed in the 'Search Results' section.

    image
    imageStd Search.jpg
    titleFig.215 Standards - Search Determinants


  10. Select the Select check box of the individual determinants and click Submit. The selected determinants will be listed in the 'Determinants' list section of the Standards screen.

    image
    imageStd Det.jpg
    titleFig.216 Standards - Selected Determinants


  11. To assign static or progressive fatigue factors for a standard, click the 'Fatigue' tab.

    image
    imageStd Fatigue.jpg
    titleFig.217 Standards - Fatigue


  12. To assign static fatigue factors, click Assign Fatigue Hour to All and type the percentage of fatigue in Fatigue Hour All field.
  13. To assign progressive fatigue factors, click Assign Individual Fatigue Hour and type the percentage of fatigue factors in Fatigue Hour Factors fields.

    Info
    titleInfo
    • If 'Assign Fatigue Hour to All' is assigned then 'Assign Individual Fatigue Hour' will be unavailable to add and vice-versa.

  14. Click Image Added to save the standard with the determinant and fatigue details.