Location Data Element Naming Conventions – It is recommended that the following naming conventions be followed to so that the user easily knows where the data element is located on the Facility Layout.
Data Element | Naming Convention | Naming Convention Example | Comment |
---|---|---|---|
Facility | FAC | DC1 | Facility ID must match EXACTLY what is configured in ProTrack Warehouse and being sent in the WMS extraction file. |
FAC-FLR | DC1-FLR1 | ||
FAC-FLR-AISLE | DC1-FLR1-04A | When two or more Aisle Paths are needed for a single rack (i.e. due to a non-passable barriers such as a security cage fence), append lowercase letters to the AISLE element. | |
FAC-FLR-AISLE-1 | DC1-FLR1-04A-1 | The ‘-1’ suffix increments (‘-2’, ‘-3’, etc.) with additional Segments on a single Aisle Path. | |
FAC-LOC | DC1-032457 | Must match the ‘To Location’ field EXACTLY being sent in the WMS extraction file. | |
FAC-FLR1-FLR2-1 | DC1-FLR1-FLR2-1 |
Table 1. Naming Conventions
...
Please refer to the Floor tab of the current “SOP for XYZ Importing” Excel spreadsheet.
Floor ID | Floor Name | Description | Start X | Start Y | End X | End Y | Width | Facility ID |
---|---|---|---|---|---|---|---|---|
1-FLR1 | 1-FLR1 | Chicago - First floor | 4000 | 2500 | 8000 | 5000 | 4000 | 1 |
2-FLR1 | 2-FLR1 | Joliet - First floor | 2000 | 2000 | 6600 | 5000 | 4600 | 2 |
Table 2. Floor Example
Info | ||
---|---|---|
| ||
|
Field | Description |
---|---|
Floor Name | Name of the floor. |
Start X | X value of the start co-ordinate of the floor. |
Start Y | Y value of the start co-ordinate of the floor. |
End X | X value of the end co-ordinate of the floor. This value should be equal to start X. |
End Y | Y value of the end co-ordinate of the floor. |
Height | This is for future development, and thus not currently available in this version of ProTrack Warehouse. |
Width | Width of the floor. |
Description | Description of the floor. |
Table 3. Floor Field Descriptions
...
Please refer to the Aisle Path tab of the current “SOP for XYZ Importing” Excel spreadsheet.
Aisle Path ID | Aisle Path Name | Start X | Start Y | End X | End Y | Floor ID | Bay Number Direction | Bay Number Scheme | Aisle Access Rule | Path Travel Rule |
---|---|---|---|---|---|---|---|---|---|---|
1-FLR1-100 | 1-FLR1-100 | 4200 | 2800 | 4300 | 2800 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | BD |
1-FLR1-101 | 1-FLR1-101 | 4200 | 3000 | 4300 | 3000 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | BD |
1-FLR1-102 | 1-FLR1-102 | 4200 | 2800 | 4200 | 3000 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | ONE_WAY |
1-FLR1-103 | 1-FLR1-103 | 4250 | 2800 | 4250 | 3000 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | ONE_WAY |
1-FLR1-104 | 1-FLR1-104 | 4300 | 2800 | 4300 | 2900 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | BD |
1-FLR1-104a | 1-FLR1-104a | 4300 | 2910 | 4300 | 3000 | 1-FLR1 | ALT_LR_ES | DUB_INC | DIRECT | BD |
Table 4. Aisle Path Examples
Field | Description |
---|---|
Aisle Path ID | ID of the aisle path. |
Aisle Path Name | Name of the aisle path. |
Start X | X value of the start co-ordinate of the aisle path. |
Start Y | Y value of the start co-ordinate of the aisle path. |
End X | X value of the end co-ordinate of the aisle path. |
End Y | Y value of the end co-ordinate of the aisle path. |
Bay Number Direction | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Bay Number Scheme | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Aisle Access Rule | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Path Travel Rule | Denotes whether the aisle can be traveled in both directions (BD), one direction (ONE_WAY), or one direction starting from the endpoint to the start point (ONE_WAY_ES)* |
Table 5. Aisle Path Field Descriptions
...
Select an aisle path to view the Aisle Path Properties.
Fig.5 Facility Layout Viewer - Aisle Path
A One-Way Aisle Path will be denoted by an Arrow on the aisle path. Equipment marked "One Way" will only be able to travel in the specified direction.
Fig.6 Facility Layout Viewer - Aisle Path, One Way
An Aisle Path with an Equipment Access Rule will be denoted by an orange color. Only equipment with the specified access rule will be able to utilize that aisle path.
Fig.7 Facility Layout Viewer - Aisle Path, Equipment Access Rule
Anchor | ||||
---|---|---|---|---|
|
A Travel Path is a connection between two different floors. In the actual warehouse, this may be at a staircase, an elevator, or just any point where two floors connect. Travel paths are similar to Aisle Paths in that they are lines over which travel is calculated, but their sole purpose is to connect two floors. Travel Paths start at one node on a starting floor and end at another node on the ending floor.
Please refer to the Travel Path tab of the current “SOP for XYZ Importing” Excel spreadsheet.
travel_id | travel_name | description | start_X | start_Y | end_X | end_Y | end_ floor_id | begin_floor_id | barrier | path_access_rule | width |
---|---|---|---|---|---|---|---|---|---|---|---|
DC1-1-2-A | DC1-1-2-A | south stairs | 1005 | 2050 | 1006 | 2050 | FLR2 | FLR1 | N | BD | 0 |
DC1-1-2-B | DC1-1-2-B | east stairs | 1500 | 1910 | 1500 | 1911 | FLR2 | FLR1 | N | BD | 0 |
DC1-2-3-A | DC1-2-3-A | service elev | 1005 | 2050 | 1006 | 2050 | FLR3 | FLR2 | N | BD | 0 |
Table 6. Travel Path Examples
Field | Description |
---|---|
Travel Path ID | ID of the Travel Path. |
Travel Path Name | Name of the Travel Path. |
Description | Description of the Travel Path. |
Start X | X value of the start coordinate of the Travel Path. |
Start Y | Y value of the start co-ordinate of the Travel Path. |
End X | X value of the end co-ordinate of the Travel Path. |
End Y | Y value of the end co-ordinate of the Travel Path. |
End Floor Id | Floor ID corresponding to the node at the X,Y coordinate specified in the End X and End Y fields. |
Begin Floor Id | Floor ID corresponding to the node at the X,Y coordinate specified in the Start X and Start Y fields. |
Barrier | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Path Access Rule | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Width | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Table 7. Travel Path Field Descriptions
...
A Travel Path is displayed as a larger grey circle overlapping a node.
Fig.6 8 Facility Layout Viewer - Travel Path
...
Repeat for all Floors.
Fig.7 9 Facility Layout Viewer - Nodes
...
Please refer to the Segment tab of the current “SOP for XYZ Importing” Excel spreadsheet.
Segment ID | Segment Name | Inset | Offset | Length | Width | Orientation | Bay_Count | Number_Scheme | Number_Direction | Aisle_ID | Floor_ID |
---|---|---|---|---|---|---|---|---|---|---|---|
1-FLR1-100-A | 1-FLR1-100-A | 1 | -2 | 98 | 4 | Left | 0 | DUB_INC | ALT_LR_ES | 1-FLR1-100 | FLR1 |
1-FLR1-104-A | 1-FLR1-104-A | 1 | -2 | 98 | 4 | Left | 0 | DUB_INC | ALT_LR_ES | 1-FLR1-104 | FLR1 |
1-FLR1-104a-A | 1-FLR1-104a-A | 111 | -2 | 88 | 4 | Left | 0 | DUB_INC | ALT_LR_ES | 1-FLR1-104a | FLR1 |
Table 8. Segment Examples
Field | Description |
---|---|
Segment ID | ID of the segment. |
Segment Name | Name of the segment. |
Aisle Name | Name of the aisle path to which the segment is associated. |
Inset | Distance from the aisle starting point to the segment. |
Offset | Distance from aisle axis to the segment. |
Width | Width of the segment. |
Length | Length of the segment. |
Numbering Scheme | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Numbering Direction | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value in from the table above. |
Start Bay Number | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Number of Bays | This is for future development, and thus not currently available in this version of ProTrack Warehouse. This is a mandatory field, so populate with the default value from the table above. |
Orientation | Orientation of the Segment as it relates to the Aisle Path. This will determine which direction will be positive and negative when setting the width of the segment. Orientation of Left will have positive distances to the left of the aisle and negative distances to the right of the aisle. Orientation of Right will have positive distances to the right of the aisle and negative distances to the left of the aisle. |
Description | Description of the segment. |
Table 9. Segment Field Descriptions
In the example illustrations that follow, the blue shaded area is the segment. Each cell is 2’ by 2’, so the width of the segment is 4’.
Fig.
...
10 Segment Orientations
Tip | ||
---|---|---|
| ||
|
...
Select a segment to view the Segment Properties.
Fig.9 11 Facility Layout Viewer - Segments
...
Please refer to the Location tab of the current “SOP for XYZ Importing” Excel spreadsheet.
Location ID | Location Name | X | Y | Floor ID | Segment ID | Level Specifier | Level Height |
---|---|---|---|---|---|---|---|
1-loc1 | 1-loc1 | 4205 | 2800 | FLR1 | 1-FLR1-100-A | ||
1-loc2 | 1-loc2 | 4220 | 2800 | FLR1 | 1-FLR1-104-A | ||
1-loc3 | 1-loc3 | 4200 | 2900 | FLR1 | 1-FLR1-104a-A |
Table 10. Location Examples
Field | Description |
---|---|
Name & ID | Must match. |
X | X co-ordinate of the location. |
Y | Y co-ordinate of the location. |
Floor ID | Must match the Floor ID that is configured in ProTrack Warehouse. |
Level Specifier | This is the To Location Level ID. Must match exactly what is being sent in the WMS extraction file. Each Level Specifier is separated by the pipe symbol . |
Level Height | This is the distance from the floor in inches for vertical travel. Must match exactly what is being sent in the WMS extraction file. Each Level Height is separated by the pipe symbol . |
Table 11. Location Field Descriptions
...
Select a location to view the Location Properties.
Fig.10 12 Facility Layout Viewer - Locations