Standards define the standard time assigned for a task. Each element of an assignment can earn time, and each line has standards applied to it based the individual determinant values and conditions.
Accessing the Standards Screen
The options in the Standards screen are available depending on the user privileges.
To access the Standards screen:
- Log in to ProTrack Warehouse.
Select Standard under the Standards menu. The Standard screen appears.
Fig.1 Standard
Standards Tab Descriptions
Tab | Descriptions |
---|
Create Standards | Displays the details of a work standard. |
Assign Determinant | Displays all the determinants associated with the selected standard. |
Fatigue | Displays all the static and progressive fatigue factors associated with the selected standard. |
Table 1. Standards Tab Descriptions
Standards Field Descriptions
Field | Description |
---|
Standard Name | Type Standard name, which is alphanumeric (Combination of Alphabets and Numbers). |
Standard Id | Auto generated by ProTrack Warehouse. |
Standard Type | Only 'WMS' type is supported. |
Calculate Horizontal Travel | To calculate horizontal travel, click ‘Yes’. If not click ‘No’. |
Calculate Vertical Travel | To calculate vertical travel, click ‘Yes’. If not click ‘No’. |
Re-trip | To calculate re-trip standard time, select the Re-trip check box and type the Re-trip Standard Time. |
Equipment Capacity Unit | Select the equipment capacity units by selecting the check boxes to the left of Lines, Units, Weight, or Volume. |
Default Equipment | Select the default equipment type from the Default Equipment list. |
Description | Type Description not more than 250 characters. |
Table 2. Standards Field Descriptions
Adding New Standards
To add a new standard:
- Type a unique Standard Name. The Standard ID is generated automatically.
- If you want to Calculate Horizontal Travel, click ‘Yes’. If not click ‘No’.
- If you want to calculate vertical travel, click ‘Yes’. If not click ‘No’.
- To calculate re-trip standard time, select the Re-trip check box and type the Re-trip Standard Time.
- Select the default equipment type from the Default Equipment list and entry capacity units by selecting the check boxes, Lines, Units, Weight, or Volume.
- Type Description.
To assign determinants to the standard, click the 'Assign Determinant' tab and the Standards screen appears with the Standard Name field and a blank ‘Determinant’ list.
Fig.2 Standard - Assign Determinants
You can search for the particular determinants by clicking the 'Select Determinant' link.
Fig.3 Standard - Select Determinants
Provide the search criteria in the Name field or selecting the Determinant level or Work from the respective lists and click . The determinants will be listed in the ‘Search Results’ section.
Fig.4 Standard - Search Determinants
Select the Select check box of the individual determinants and click . The selected determinants will be listed in the ‘Determinants’ list section of the Standards screen.
Fig.5 Standard - Selected Determinants
To assign static or progressive fatigue factors for a standard, click the 'Fatigue' tab.
Fig.6 Standard - Fatigue
- To assign static fatigue factors, click Assign Fatigue Hour to All and type the percentage of fatigue in Fatigue Hour All field.
To assign progressive fatigue factors, click Assign Individual Fatigue Hour and type the percentage of fatigue factors in Fatigue Hour Factors fields.
Info |
---|
|
- If 'Assign Fatigue Hour to All' is assigned then 'Assign Individual Fatigue Hour' will be unavailable to add and vice-versa.
|
- Click to save the standard with the determinant and fatigue details.
Searching Standards
To search for particular Standards:
Click in the Standards screen and the Search Standard screen appears.
Fig.7 Standard - Search Standards
Type either Standard Name or select the standard type from the Standard Type list.
Tip |
---|
|
- To list Standards with names starting with a particular character, enter the character into the field. For example, to search standards starting with the character 'C', enter 'C' in the Standard Name to list standards with names starting with C.
- If no search criteria are specified all the standards will be listed in the 'Standards Search Results' section.
|
- Click in the Search Standard screen and the records for the selected criteria are listed in the ‘Standards Search Results’ section.
Fig.8 Standard - Search Results
Viewing & Editing Standards
To view and edit the standards:
- Search and list the standards you want to view or edit in the ‘Standards Search Results’ section.
- Click the selected standard ID link from the ‘Standard Search Results’ section. The details of the standard appear in the corresponding fields in the Standards screen.
- Change the required fields.
Click to save the changes.
Tip |
---|
|
- If you have made the changes in the fields and do not want to save the details, click before you save the changes.
- If you want to delete assigned determinant, click on the corresponding check box and click .
- If you want to add a standard, click to clear the fields and to bring the screen to add mode.
- These changes will only be applied to assignments worked after the changes have been made, unless on the Daily Inquiry screen is invoked.
|
Deleting Standards
Info |
---|
|
- Standards must be removed from selector(s) and all determinant(s) tied to the standard must be removed before they can be deleted.
- Standards that are linked to any other records in the system cannot be deleted (i.e. standards that have been used by an assignment to calculate standard earned time).
|
To delete a standard:
- Go to the Selector screen and search for all selectors that use the standard which will be deleted. The selector(s) will be listed in the 'Selector Search Results' section.
- Select the check box to the left of each selector(s) and click .
Fig.9 Standard - Deleting Selectors
- Go to the Standard screen and search for the standard that will be deleted. Click on the Standard ID link from the 'Standard Search Results' section and the details of the standard will be populated above.
- Click 'Assign Determinant' tab and select the Delete check box to select all the determinants.
Fig.10 Standard - Deleting Determinants - Click to remove all determinants from the standard.
- Select the check box to the left of the Standard ID in the 'Standard Search Results' section.
Fig.11 Standard - Selecting Standard
- Click to delete the standard.